Noack volatility test
Test to determine evaporation loss of lubricants in high-temperature service
Test to determine evaporation loss of lubricants in high-temperature service
The Noack volatility test, named after Kurt Noack, determines the evaporation loss of lubricants in high-temperature service. This test is standardized as ASTM D5800.
In this test, a sample is heated at 250 °C for 60 minutes with a constant flow of air over it. The weight fraction lost is the result for the Noack volatility test.
As the lighter hydrocarbon fraction of motor oils evaporate, the viscosity of the remaining oil increases, contributing to poor circulation, reduced fuel economy, increased oil consumption, wear and tailpipe emissions.
References
References
- K. Noack. (1936). "Eine neue Laboratoriumsmethode zur Ermittlung der Verdampfbarkeit von Schmierölen für Verbrennungskraftmaschinen". Angew. Chem..
- (2015). "ASTM D5800-15a, Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method". ASTM International.
This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.
Ask Mako anything about Noack volatility test — get instant answers, deeper analysis, and related topics.
Research with MakoFree with your Surf account
Create a free account to save articles, ask Mako questions, and organize your research.
Sign up freeThis content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.
Report