From Surf Wiki (app.surf) — the open knowledge base
Nanotomography
Nanotomography, much like its related modalities tomography and microtomography, uses x-rays to create cross-sections from a 3D-object that later can be used to recreate a virtual model without destroying the original model, applying Nondestructive testing. The term nano is used to indicate that the pixel sizes of the cross-sections are in the nanometer range
Nano-CT beamlines have been built at 3rd generation synchrotron radiation facilities, including the Advanced Photon Source of Argonne National Laboratory, SPring-8, and ESRF from early 2000s. They have been applied to wide variety of three-dimensional visualization studies, such as those of comet samples returned by the Startdust mission, mechanical degradation in lithium-ion batteries, and neuron deformation in schizophrenic brains.
Although a lot of research is done to create nano-CT scanners, currently there are only a few available commercially. The SkyScan-2011 has a range of about 150 to 250 nanometers per pixel with a resolution of 400 nm and a field of view (FOV) of 200 micrometers. The Xradia nanoXCT has a spatial resolution of better than 50 nm and a FOV of 16 micrometers.
At the Ghent University, the UGCT team developed a nano-CT scanner based on commercially available components. The UGCT facility is an open nano-CT facility giving access to scientists from universities, institutes and industry.
References
References
- De Andrade, V, Deriy, A, Wojcik, MJ, Gürsoy, D, Shu, D, Fezzaa, K, and De Carlo, F. (2016) "Nanoscale 3D imaging at the Advanced Photon Source", SPIE Newsroom [https://doi.org/10.1117/2.1201604.006461 DOI:10.1117/2.1201604.006461].
- Takeuchi, A, Uesugi, K, Takano, H, and Suzuki, Y (2002) "Submicrometer-resolution three-dimensional imaging with hard x-ray imaging microtomography", Rev. Sci. Instrum. 73, 4246 [https://doi.org/10.1063/1.1515385 DOI:10.1063/1.1515385].
- Schroer, C G, Meyer, J, Kuhlmann, M, Benner, B, Günzler, T F, Lengeler, B, Rau, C, Weitkamp, T, Snigirev, A and Snigireva, I. (2002) "Nanotomography based on hard x-ray microscopy with refractive lenses", Appl. Phys. Lett. 81, 1527, [https://doi.org/10.1063/1.1501451 DOI:10.1063/1.1501451].
- Flynn, G J et al. (2006) "Elemental compositions of Comet 81P/Wild 2 samples collected by Stardust", Science 314, 1731-1735 [https://doi.org/10.1126/science.1136141 DOI:10.1126/science.1136141].
- Müller, S, Pietsch, P, Brandt, B, Baade, P, De Andrade, V, De Carlo, F, and Wood, V. (2018) "Quantification and modeling of mechanical degradation in lithium-ion batteries based on nanoscale imaging", Nat. Commun. 9, 2340 [https://doi.org/10.1038/s41467-018-04477-1 DOI:10.1038/s41467-018-04477-1].
- Mizutani, R et al. (2019) "Three-dimensional alteration of neurites in schizophrenia", Transl. Psychiatry 9, 85 [https://doi.org/10.1038/s41398-019-0427-4 DOI:10.1038/s41398-019-0427-4].
- [http://www.skyscan.be SkyScan-2011]
- [http://www.xradia.com Xradia nanoXCT]
- Tkachuk, A, Duewer, F, Cui, H, Feser, M, Wang, S and Yun, W (2007) "X-ray computed tomography in Zernike phase contrast mode at 8 keV with 50-nm resolution using Cu rotation anode X-ray source", ''Z. Kristallogr.'' 222. pp. 650-655
- [http://www.ugct.ugent.be UGCT-website]
This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.