Light reflectance value
Measure of light reflected from a surface
Measure of light reflected from a surface

In architecture, light reflectance value (LRV), is a measure of visible and usable light that is reflected from a surface when illuminated by a light source.{{cite web
LRVs are frequently reported on paint chips or paint samples. The values are used by lighting designers to determine the number and type of light fixtures needed to provide proper lighting for interior spaces.
Guidance
Designers of buildings must comply with the building codes applicable to the structure under consideration. Since 2004 guidance has existed on access to and use of buildings. The guidance is particularly concerned with provisions to assist the disabled, including those who are visually impaired. The guidance highlights the need for certain surfaces and features to contrast visually with their surroundings. Areas of particular interest are wall-to-ceiling and wall-to-floor junctions, exposed edges of sloping floors, seating and its surroundings, leading edges of doors, door opening furniture and door surfaces, sanitary fittings and grab bars.
This is relevant to a wide range of non-residential buildings, such as hospitals, schools, hotels, and theatres.
Codes of practice
The British Standards Institute's guidance in the Regulations and in the relevant Codes of Practice, BS 8300:2018, is that adequate visual contrast is provided if the light reflectance values of the contrasting areas differ by at least thirty points. The current British Standard for the measurement of LRV is BS8493:2008+A1:2010.
The Americans with Disabilities Act Standards for Accessible Design does not recommend a light reflectance value for contrast on signage with words or pictograms, but instead it provides that "characters shall contrast with their background with either light characters on a dark background or dark characters on a light background" in § 703.5.1
The International Code Council utilizes the ADA approach and does not use a light reflectance value in the 2017 update to the standards for ICC A117.1 in § 703.5.3.2
The United Nations Economic Commission for Europe uses a difference of sixty points between the LRVs for the contrast requirement of signage in "Railway Applications — Design for PRM Use - General Requirements — Part 1: Contrast."
Manufacturers are advised by the Guild of Architectural Ironmongery to publish the LRV for their products.
References
- Bradshaw, Vaugh, P.E. Building Control Systems. New York: John Wiley & Sons, Inc. Second Edition, 1993.
References
- "Specification Guidelines, Design Service & CPD". gradusworld.com.
- "ADA Standards for Accessible Design (2010)".
- "International Code Council 'Accessible and Usable Buildings and Facilities (2017)'".
- "United Nations Economic Commission for Europe 'Railway Applications — Design for PRM Use - General Requirements — Part 1: Contrast.'".
This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.
Ask Mako anything about Light reflectance value — get instant answers, deeper analysis, and related topics.
Research with MakoFree with your Surf account
Create a free account to save articles, ask Mako questions, and organize your research.
Sign up freeThis content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.
Report