Two circular coil device which creates a homogeneous magnetic field


A Helmholtz coil is a device for producing a region of nearly uniform magnetic field, named after the German physicist Hermann von Helmholtz. It consists of two electromagnets on the same axis, carrying an equal electric current in the same direction. Besides creating magnetic fields, Helmholtz coils are also used in scientific apparatus to cancel external magnetic fields, such as the Earth's magnetic field.

Description
A Helmholtz pair consists of two identical circular magnetic coils that are placed symmetrically along a common axis, one on each side of the experimental area, and separated by a distance h equal to the radius R of the coil. Each coil carries an equal electric current in the same direction.
Setting h=R, which is what defines a Helmholtz pair, minimizes the nonuniformity of the field at the center of the coils, in the sense of setting \partial^{2}B/\partial x^{2} = 0 (meaning that the first nonzero derivative is \partial^{4}B/\partial x^{4} as explained below), but leaves about 7% variation in field strength between the center and the planes of the coils. A slightly larger value of h reduces the difference in field between the center and the planes of the coils, at the expense of worsening the field's uniformity in the region near the center, as measured by \partial^{2}B/\partial x^{2}.
In some applications, a Helmholtz coil is used to cancel out the Earth's magnetic field, producing a region with a magnetic field intensity much closer to zero.
Mathematics
bisecting the current loops. Note the field is approximately uniform in between the coil pair. (In this picture the coils are placed one beside the other: the axis is horizontal.)]]
The calculation of the exact magnetic field at any point in space is mathematically complex and involves the study of Bessel functions. Things are simpler along the axis of the coil-pair, and it is convenient to think about the Taylor series expansion of the field strength as a function of x, the distance from the central point of the coil-pair along the axis. By symmetry, the odd-order terms in the expansion are zero. By arranging the coils so that the origin x=0 is an inflection point for the field strength due to each coil separately, one can guarantee that the order x^2 term is also zero, and hence the leading non-constant term is of order x^4. The inflection point for a simple coil is located along the coil axis at a distance R/2 from its centre. Thus the locations for the two coils are x=\pm R/2.
The calculation detailed below gives the exact value of the magnetic field at the center point. If the radius is R, the number of turns in each coil is n and the current through the coils is I, then the magnetic field B at the midpoint between the coils will be given by
: B = {\left ( \frac{4}{5} \right )}^{3/2} \frac{\mu_0 n I}{R},
where \mu_0 is the permeability of free space .
Derivation
Start with the formula for the on-axis field due to a single wire loop which is itself derived from the Biot–Savart law:
: B_1(x) = \frac{\mu_0 I R^2}{2(R^2+x^2)^{3/2}}=\xi(x) \frac{\mu_0 I}{2R}.
Here
:\mu_0; = the permeability constant = 4\pi \times 10^{-7} \text{ T}\cdot\text{m/A} = 1.257 \times 10^{-6} \text{ T}\cdot\text{m/A},
:I; = coil current, in amperes, :R; = coil radius, in meters, :x; = coil distance, on axis, to point, in meters, :\xi(x)=[1+(x/R)^2]^{-3/2};is the distance dependent, dimensionless coefficient.
The Helmholtz coils consists of n turns of wire, so the equivalent current in a one-turn coil is n times the current I in the n-turn coil. Substituting nI for I in the above formula gives the field for an n-turn coil:
: B_1(x) = \xi(x)\frac{\mu_0 n I}{2R}.
For x\ll R, the distance coefficient \xi(x)=[1+(x/R)^2)]^{-3/2};can be expanded in Taylor series as:\xi(x)=1-\frac{3}{2}(x/R)^2+\mathcal{O}((x/R)^4).In a Helmholtz pair, the two coils are located at x=\pm R/2, so the B-field strength at any x would be:
: \begin{align} B(x) &= \frac{\mu_0 n I}{2R}\left[\xi(x-R/2)+\xi(x+R/2)\right] \ &=\frac{\mu_0 n I}{2R}\left([1+(x/R-1/2)^2]^{-3/2}+[1+(x/R+1/2)^2]^{-3/2}\right) \ \end{align} The points near the center (halfway between the two coils) have x\ll R, and the Taylor series of \xi(x-R/2)+\xi(x+R/2) is:(16 \sqrt 5)/25-(x/R)^4(2304 \sqrt 5)/3125+\mathcal O ((x/R)^6)\approx 1.43-1.65(x/R)^4+\mathcal O ((x/R)^6).
Time-varying magnetic field
Most Helmholtz coils use DC (direct) current to produce a static magnetic field. Many applications and experiments require a time-varying magnetic field. These applications include magnetic field susceptibility tests, scientific experiments, and biomedical studies (the interaction between magnetic field and living tissue). The required magnetic fields are usually either pulse or continuous sinewave. The magnetic field frequency range can be anywhere from near DC (0 Hz) to many kilohertz or even megahertz (MHz). An AC Helmholtz coil driver is needed to generate the required time-varying magnetic field. The waveform amplifier driver must be able to output high AC current to produce the magnetic field.
Driver voltage and current
I=\left ( \frac{5}{4} \right )^{3/2}\left ( \frac{BR}{\mu_0n} \right )
Use the above equation in the mathematics section to calculate the coil current for a desired magnetic field, B.
where \mu_0 is the permeability of free space or 4\pi \times 10^{-7} \text{ T}\cdot\text{m/A} = 1.257 \times 10^{-6} \text{ T}\cdot\text{m/A},
I; = coil current, in amperes,
R; = coil radius, in meters,
n = number of turns in each coil.

Then calculate the required Helmholtz coil driver amplifier voltage:
:V=I\sqrt{\bigl[\omega\bigl(L_1+L_2\bigr)\bigr]^2+\bigl(R_1+R_2\bigr)^2}
where
- I is the peak current,
- ω is the angular frequency or ,
- L1 and L2 are the inductances of the two Helmholtz coils, and
- R1 and R2 are the resistances of the two coils.
High-frequency series resonant
Generating a static magnetic field is relatively easy; the strength of the field is proportional to the current. Generating a high-frequency magnetic field is more challenging. The coils are inductors, and their impedance increases proportionally with frequency. To provide the same field intensity at twice the frequency requires twice the voltage across the coil. Instead of directly driving the coil with a high voltage, a series resonant circuit may be used to provide the high voltage.{{Cite web | access-date = 2016-02-25
:f_0=\frac{1}{2\pi\sqrt{\left (L_1+L_2\right )C}} :C=\frac{1}{\left ( 2\pi f_0\right )^2\left ( L_1 +L_2\right )}
Anti-Helmholtz coil
When the pair of two electromagnets of a Helmholtz coil carry an equal electric current in the opposite direction, it is known as anti-Helmholtz coil, which creates a region of nearly uniform magnetic field gradient, and is used for creating magnetic traps for atomic physics experiments.
In an anti-Helmholtz pair, the B-field strength at any x would be: : \begin{align} B(x) &= \frac{\mu_0 n I}{2R}\left[\xi(x-R/2)-\xi(x+R/2)\right] \ &=\frac{\mu_0 n I}{2R}\left([1+(x/R-1/2)^2]^{-3/2}-[1+(x/R+1/2)^2]^{-3/2}\right) \ \end{align} The points near the center (halfway between the two coils) have x\ll R, and the Taylor series of \xi(x-R/2)-\xi(x+R/2) is:(x/R)(96 \sqrt 5)/125-(x/R)^3(512 \sqrt 5)/625+\mathcal O ((x/R)^5)\approx 1.72(x/R)-1.83(x/R)^3+\mathcal O ((x/R)^5).
Maxwell coils

Main article: Maxwell coil
To improve the uniformity of the field in the space inside the coils, additional coils can be added around the outside. James Clerk Maxwell showed in 1873 that a third larger-diameter coil located midway between the two Helmholtz coils with the coil distance increased from coil radius R to \sqrt{3}R can reduce the variance of the field on the axis to zero up to the sixth derivative of position. This is sometimes called a Maxwell coil.
References
References
- (2006). "Hall-effect sensors : theory and applications". Elsevier/Newnes.
- [http://www.purcellsolutions.com/2011/06/purcell-physics-problem-6-13-solution.html Helmholtz Coil in CGS units]{{webarchive. link. (March 24, 2012)
- "Electromagnetism".
- [http://www.circuitcellar.com/library/print/0606/Wotiz191/5.htm "Earth Field Magnetometer: Helmholtz coil"] by Richard Wotiz 2004 {{webarchive. link. (June 28, 2007)
- "Magnetic Field of a Current Loop".
- Yang, KC. "High frequency Helmholtz coils generate magnetic fields".
- "ログイン - ASACUSA MUSASHI group".
- (Nov 1994). "The Calculation and Measurement of Helmholtz Coil Fields".
This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.
Ask Mako anything about Helmholtz coil — get instant answers, deeper analysis, and related topics.
Research with MakoFree with your Surf account
Create a free account to save articles, ask Mako questions, and organize your research.
Sign up freeThis content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.
Report