Skip to content
Surf Wiki
Save to docs
general/electrophoresis

From Surf Wiki (app.surf) — the open knowledge base

Difference gel electrophoresis


Difference gel electrophoresis (DIGE) is a form of gel electrophoresis where up to three different protein samples can be labeled with size-matched, charge-matched spectrally resolvable fluorescent dyes (for example Cy3, Cy5, Cy2) prior to two dimensional gel electrophoresis.Unlü M, Morgan ME, Minden JS. Difference gel electrophoresis: a single gel method for detecting changes in protein extracts. Electrophoresis. 1997 Oct;18(11):2071-7. PMID 9420172

Procedure

The three samples are mixed and loaded onto IEF (isoelectric focusing chromatography) for first dimension and the strip is transferred to a SDS PAGE. After the gel electrophoresis, the gel is scanned with the excitation wavelength of each dye one after the other, so each sample can be seen separately (if we scan the gel at the excitation wavelength of the Cy3 dye, we will see in the gel only the sample that was labeled with that dye). This technique is used to see changes in protein abundance (for example, between a sample of a healthy person and a sample of a person with disease), post-translational modifications, truncations and any modification that might change the size or isoelectric point of proteins. The binary shifts might be left to right (change in isoelectric point), vertical (change in size) or diagonal (change in both size and isoelectric point). Reciprocal Labeling is done to make sure the changes seen are not due to dye-dependent interactions.

Advantages

It overcomes limitations in traditional 2D electrophoresis that are due to inter-gel variation. This can be considerable even with identical samples. Since the proteins from the different sample types (e.g. healthy/diseased, virulent/non-virulent) are run on the same gel they can be directly compared. To do this with traditional 2D electrophoresis requires large numbers of time-consuming repeats.

Standards

In experiments comprising several gels, a common technique is to include an internal standard in each gel. The internal standard is prepared by mixing together several or all of the samples in the experiment. This allows the measurement of the abundance of a protein in each sample relative to the internal standard. Since the amounts of each protein in the internal standard is known to be the same in every gel, this method reduces inter-gel variation.

References

References

  1. (2003). "A novel experimental design for comparative two-dimensional gel analysis: Two-dimensional difference gel electrophoresis incorporating a pooled internal standard". Proteomics.
Wikipedia Source

This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.

Want to explore this topic further?

Ask Mako anything about Difference gel electrophoresis — get instant answers, deeper analysis, and related topics.

Research with Mako

Free with your Surf account

Content sourced from Wikipedia, available under CC BY-SA 4.0.

This content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.

Report