Contraction stress test

Medical test on pregnant women


Summary

Medical test on pregnant women

FieldValue
nameContraction stress test
purposefetal test (heart rate)
DiseasesDB
ICD10
MedlinePlus
eMedicine
OPS301
LOINC

A contraction stress test (CST) is performed near the end of pregnancy (34 weeks' gestation) to determine how well the fetus will cope with the contractions of childbirth. The aim is to induce contractions and monitor the fetus to check for heart rate abnormalities using a cardiotocograph. A CST is one type of antenatal fetal surveillance technique.

During uterine contractions, fetal oxygenation is worsened. Late decelerations in fetal heart rate occurring during uterine contractions are associated with increased fetal death rate, growth retardation and neonatal depression. This test assesses fetal heart rate in response to uterine contractions via electronic fetal monitoring. Uterine activity is monitored by tocodynamometer.

Medical uses

The CST is used for its high negative predictive value. A negative result is highly predictive of fetal wellbeing and tolerance of labor. The test has a poor positive predictive value with false-positive results in as many as 30% of cases. A positive CST indicates high risk of fetal death due to hypoxia

Contraindications

This "stress test" is usually not performed if there are any signs of premature birth, placenta praevia, vasa praevia, cervical incompetence, multiple gestation, previous classic caesarian section. Other contraindications include but are not limited to previous uterine incision with scarring, previous myomectomy entering the uterine cavity, and PROM. Any contraindication to labor is contraindication to CST.

Procedure

CST is performed weekly, This test is done in hospital or clinic setting. External fetal monitors are put in place and then either nipple stimulation or IV pitocin (oxytocin) is used to stimulate uterine contractions.

Nipple stimulation

This is a procedure that relies on endogenous release of oxytocin following nipple stimulation, and is conducted by the patient. The nurse instructs the patient on the procedure, as follows. One nipple is massaged gently through clothing until a contraction begins, or for a maximum of 2 minutes. If at least 3 contractions in 10 minutes is not achieved, then the patient rests for 5 minutes and the other nipple is stimulated.

Oxytocin challenge test (OCT)

If adequate contractions (at least 3 in 10 minutes) cannot be achieved with nipple stimulation, an oxytocin challenge test may be performed. It involves the intravenous administration of exogenous oxytocin to the pregnant woman. The target is to achieve around three contractions every ten minutes.

Interpretation

ResultInterpretation
Positivelast=Evanseditor=Arthur T.title=Manual of obstetricsyear=2007publisher=Wolters Kluwer / Lippincott Williams & Wilkinslocation=Philadelphiaisbn=9780781796965pages=587edition=7th}}
Negativelast=Andersoneditor=Jean R.title=A guide to the clinical care of women with HIVyear=2005publisher=U.S. Dept. of Health & Human Services, Health Resources & Services Administration, HIV/AIDS Bureaulocation=Rockville, MDisbn=9780160726118pages=270edition=2005}}
Equivocal—SuspiciousPresence of late decelerations with fewer than 50% of contractions or significant variable decelerations. Requires repeat testing on following day.
Equivocal—TachysystolePresence of contractions that occur more frequently than every 2 minutes or last longer than 90 seconds in the presence of late decelerations. Requires repeat testing on following day.
Equivocal—UnsatisfactoryFewer than three contractions occur within 10 minutes, or a tracing quality that cannot be interpreted. Requires repeat testing on following day.

History

The CST was the first antenatal surveillance test that was developed after the development of the cardiotocograph. The oxytocin challenge test was first described in 1972 and was standardised in 1975 when the parameters of contraction number and frequency were given.

Historically, a CST was done after a non reactive NST. Today, a biophysical profile (BPP) is usually performed.

References

References

  1. (2008). "Danforth's obstetrics and gynecology". Lippincott Williams & Wilkins.
  2. (2007). "Current diagnosis & treatment : Obstetrics & gynecology". McGraw-Hill.
  3. III, Frances Talaska Fischbach, Marshall Barnett Dunning. (2009). "A manual of laboratory and diagnostic tests". Wolters Kluwer Health/Lippincott Williams & Wilkins.
  4. ((Lagrew DC Jr)). (March 1995). "The contraction stress test.". Clinical Obstetrics and Gynecology.
  5. Tao Le. (2008). "First aid for the family medicine boards". McGraw-Hill Medical.
  6. Munden, Julie. (2005). "Professional guide to diagnostic tests". Lippincott Williams & Wilkins.
  7. American College of Obstetricians and Gynecologists (ACOG). (1999). Antepartum fetal surveillance (Practice Bulletin No. 9). Washington, DC: Author.
  8. ((Association of Women's Health, Obstetric, and Neonatal Nurses)). (2005). "Fetal Heart Monitoring: Principles and Practices". Kendall/Hunt Publishing Co..
  9. Evans. (2007). "Manual of obstetrics". Wolters Kluwer / Lippincott Williams & Wilkins.
  10. Anderson. (2005). "A guide to the clinical care of women with HIV". U.S. Dept. of Health & Human Services, Health Resources & Services Administration, HIV/AIDS Bureau.
  11. (September 1972). "Clinical experience with the oxytocin challenge test". Am. J. Obstet. Gynecol..
Wikipedia Source

This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.

Want to explore this topic further?

Ask Mako anything about Contraction stress test — get instant answers, deeper analysis, and related topics.

Research with Mako

Free with your Surf account

Content sourced from Wikipedia, available under CC BY-SA 4.0.

This content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.

Report